Epson 410 User Manual
Page 51

Chapter 5
Printer Commands
))))))))))))))))))))))))))))))))))))))))))))
))))))))))))))))))))))))))))))))))))))))))))
410 Operators Manual
45
5.3.4 REAL-TIME CLOCK
^A
^D
Command
30
Change Clock: Use the sequence below to set the time and date of the optional
real-time socket:
^D30 <CR>
HH:MM:SS <CR>
DD/MN/YR/W <CR>
Where the above parameters are defined as:
HH = hours (24 hour format) DD = day
MM = minutes MN = month
SS = seconds YR = last 2 of year
W = day of the week
1 = SUN
2 = MON
3 = TUE
4 = WED
5 = THR
6 = FRI
7 = SAT
The optional clock chip produces a string of data that is accessed through use of a TSN
of 0 and a TSP dependent on the data required of the clock chip.
The data string is shown below...
HH:MM:SS MN/DD/YR XXX DD/MN/YR XXX
...where xxx is the day of the week.
These values should be inserted into the Field parameters for proper clock text access:
Clock Field Parameters
TSN
TSP
CC
DATA
0
1
8
HH:MM:SS
0
10
8
MN/DD/YR
0
19
3
Day of Week
0
23
8
DD/MN/YR
0
32
3
Day of Week
Table 10