4 using the product 2.4.1 startup – EcoFlow SmGenerator User Manual

Page 13

Advertising
background image

9

1. Turn the fuel cap breather valve knob to "ON".

2. Turn the Engine Switch to "ON".

The generator can be started using any of the four methods below:

a) Electric Start Switch

Press and hold the Electric Start Switch for 2 seconds to execute the

start-up program and start up the generator.

Tips: To save battery power consumption, when the Engine Switch is

at the "ON" position, if the generator fails to start up, the power will be

disconnected after 3 mins and the display screen will switch off. In this

situation, press the start button to activate the screen display to then re-

enable the Electric Start Switch.

b) Manual start

Pull the Manual Starter Grip until the line tightens and push it by force.

Tips: When starting by hand, it is necessary to hold the generator still to prevent it from tilting or

tumbling during the pull-push process.

c) Self-start, see paragraph 2.4.4
d) Starting through the app, see paragraph 2.4.5

Tips: When the ambient temperature is below 32

℉(

0 °C), the engine will need to warm up for three

minutes after being started, during which time no load should be loaded.

Read the Safety Guidelines before use.
Do not use the generator in a closed space as the exhaust fumes may result in a loss of

consciousness or even death. Use it in a well-ventilated place.

Do not connect the AC Output Socket with any electrical equipment before starting the generator.

Tips: The generator is used at 5

-104

(

-15

—40

℃).

The generator can operate at rated power under

standard atmospheric conditions (“standard atmospheric conditions” - ambient temperature 77

(25

℃)

- atmospheric pressure 100KPA - relative humidity 30%). Once the temperature, humidity and altitude
exceed standard atmospheric conditions, the output of the generator will drop. Using for a long time in
a high temperature (above 95

℉ /

35

)

environment will affect the service life of the generator and the

built-in battery. Moreover, if the generator is used in any narrow space, its load must be reduced as the
generator cooling is affected.

2.4 Using the Product

2.4.1 Startup

Manual start

Danger

Advertising