Faults and troubleshooting – EcoFlow SmGenerator User Manual

Page 23

Advertising
background image

19

Errors

Content of Tips

Error Type

Possible Causes

Recovery Methods

Unable

to

start

Fuel system

The fuel cap breather valve knob is in the

OFF position

Turn the fuel cap breather valve knob

to "ON"

The Engine Switch is in the OFF position

Turn the Engine Switch to "ON"

There is no fuel left

Refueling

The generator set was not properly

prepared for storage, or the gasoline was

not evacuated, or the quality of injected

fuel was poor.

Empty the fuel tank and carburetor and

refill with fresh fuel

The fuel filter is blocked. Carburetor faults,

ignition failure, or stuck valves, etc.

Send the generator set to your service

dealer, or refer to the Service Manual

Oil Alert Indicator

stays on

Engine oil system

Low engine oil level. The engine oil alarm

system may turn off the engine.

Add engine oil

Electrical system

The spark plug is faulty, dirty or have

improper clearance

Adjust the clearance or replace the spark

plug

The spark plug has been moistened by the

fuel (spilled outside the engine)

Dry the spark plug with air and reinstall it

Oil Alert Indicator

stays on

Communication failure

Send the generator set to your service

dealer, or refer to the Service Manual

Lack of battery power or the battery is

damaged

Pull by hand to start or replace the battery

CO exceeding

specified standard

values

Poor ventilation

Turn off the generator and improve

ventilation

No

output

AC overload protection

Load-related problems

Remove the problem load, shut down and

restart

DC overload protection

Load-related problems

Remove the problem load, shut down and

restart

Over-temperature

protection

The air inlet is blocked or the ambient

temperature is too high or the load is too large

Check the air inlet or remove it from the high

temperature environment or reduce the load

5. Faults and Troubleshooting

Communication failure:

Communication failures may occur in two specific situations, as detailed below.

1) Normal failure:

When the generator is connected to DELTA Max or DELTA Pro, if the generator goes

into sleep mode, a communication failure will occur. In this situation, press a button to activate the
generator and the communication failure will disappear.

2) Abnormal failure:

If the communication failure does not disappear once the generator has been

activated or while the generator is running, this could indicate that the failure has been caused by a

problem with the generator.
If any alert occurs during the use of this product and if the alert icon does not disappear after the

foregoing methods are attempted or the product is restarted, please stop using it immediately.
If the above information still fails to solve your problem, please contact our professional service

personnel for further support.

Icon stays on

Icon stays on

The icon stays on

Icon flashes

Icon flashes

Icon flashes

The icon stays on

Battery over-

temperature

The air inlet is blocked or the ambient

temperature is too high or the load is too large

Check the air inlet or remove it from the high

temperature environment or reduce the load