Caution

4.5 Transportation

When moving, storing or operating the generator, do not place it on its side. The engine oil may leak
and damage the engine or your property.
If the generator is constantly running, allow it to cool before being loaded onto the transport vehicle.

Hot engines and waste systems may cause burns and can cause certain materials to ignite. To prevent
fuel spills during transport, position the generator vertically in the standard operating position, and
turn the engine switch and the fuel cap breather valve knob to the “OFF” position.
During transportation, take care not to let the generator fall or be impacted.

If the generator is stored with fuel in the fuel tank and carburetor, conduct servicing as required in the
table below before using again.

4.4 Use after storage

Storage Duration

Recommended Servicing Procedure to Prevent Difficult Startups

Evacuate the fuel and inject fresh fuel

Drain the fuel from Sediment Bowl

No preparation needed

Evacuate the fuel and inject fresh fuel

Drain the fuel from Carburetor Drain Cup

Drain the fuel from Sediment Bowl

Evacuate the fuel and inject fresh fuel

Drain the original fuel into a suitable storage container after moving it out of storage

and inject fresh fuel before starting it.

Loosen and remove the oil drain bolt and drain all the fuel out of the carburetor. Drain the fuel into a

suitable container, and screw in and tighten the oil drain bolt.

After turning off the Engine Switch, remove the Sediment Bowl, empty the gasoline from the bowl,

reinstall the Sediment Bowl and tighten it.

Drain the fuel from Carburetor Drain Cup

Within one month

One to two months

Two months to one

year

Over one year