Venting fireplace inserts, Initial installation – Enviro C-10637 User Manual

Page 14

Advertising
background image

14

Install sealed throat connector or

flashing to prevent leakage of room air

up through chimney.

DV Only: Before installing vent

liners, mark each liner on both ends

to designate which is the intake and

the exhaust.
Measure the height of the chimney

beforehand

and

purchase

the

appropriate kit. Never attempt to over-

stretch a flexible liner to accommodate

the height of the chimney.

Any flue damper must be removed or

blocked permanently in the open

position.
The chimney must be clean, in good

working order and constructed of non-

combustible materials.
Make sure that all chimney cleanouts

are tight fitting and will not permit air to

leak into the chimney

�� �����

�� �����

Initial Installation

QUALIFIED INSTALLERS ONLY

V

ENTING

F

IREPLACE

I

NSERTS

:

The ENVIRO SIENNA may be installed and vented into any solid fuel fireplace that has been installed in

accordance with the National, Provincial/State and local building codes and has been constructed of non-

combustible materials. Before starting refer to P

REPARING

Y

OUR

S

IENNA

F

OR

I

NSTALLATION

and C

ONVERTING

A

D

IRECT

V

ENT

F

IREPLACE

TO

A

B-V

ENT

F

IREPLACE

.

An approved chimney liner and rain cap must be used. A throat connector or flashing must be installed

to ensure a tight seal, top performance, safety and efficiency. Carefully follow the manufacturer’s

instructions that accompany the chimney liner kit.
Remove the vent collar plate from the top of the insert and connect it securely with sheet metal screws

and/or hose clamps. Check for any tears in the liner at this point. IMPORTANT: The screws that hold

the vent collar plate in its approved position must be installed.

Figure 12: Installation of Sienna DV and BV.