Trouble shooting – Enviro C-10637 User Manual

Page 24

Advertising
background image

Trouble Shooting

Problem

Possible Cause

Solution

Spark will not arc

to the pilot after

repeatedly pressing

the spark ignitor

Defective piezo ignitor

• Check connections to ignitor.

• If ignitor connections are good but no spark, replace

ignitor.

Broken spark electrode

• Check for broken ceramic insulation, replace electrode if

broken.

Mis-aligned spark electrode • If spark is not arcing from electrode to pilot, loosen the

screws on the pilot base, adjust and tighten.

Pilot will not remain

lit

Problem with thermocouple

circuit

• Check for proper connection of the thermocouple to the

rear of the valve. If loose, fully tighten.

• Check pilot for full flame impingement around

thermocouple. If flame is too small, check gas pressure,

adjust pilot rate screw, check pilot head for damage.

• Check thermocouple voltage at valve. It must be greater

than 5 mV. If low, replace thermocouple.

Air in gas line (pilot dies

while knob is depressed)

• Bleed line.

• Check gas line pressure.

• Contact dealer.

Burners will not

remain lit

Problem with thermopile

circuit

• Check gas line pressure .

• Check for flame impingement on thermopile. If low, see

“Pilot will not remain lit”.

• Check thermopile for minimum of 300 mV when burner is

switched on.

• Check wiring to thermostat for breaks.

BV ONLY:

• Check for spillage at draft hood that may trip spill switch

Flame lifting

Leak in vent pipe

• Check for leaks in vent connections.

Improper vent configuration • Check vent configuration with manual.
Terminal may be

recirculating flue gases

• Check to see if terminal is on correctly.

• May need to install high wind termination cap.

• Contact dealer.

Glass fogs up

Normal Condition: after the appliance warms up the glass will clear.

**Due to additives in gas, glass may get hazy during operation**

Clean as needed

Blue Flames

Normal during start up: flames will yellow as the fireplace heats up.

May have too many embers on burner.

Flames are burning

“dirty” or sooting

Flame impingement

• Check log positioning.

• Increase primary air by opening the venturi shutter and/or

by opening the vent restrictor.

See also “Burners will not remain lit.”

Remote control

doesn’t work

Problem with the remote

• One or more of the batteries are dead. See remote control

instructions.

Problem with fireplace

• The on/off switch is turned to OFF.

• The gas control valve is turned to PILOT or OFF.

• The pilot has gone out.

BV ONLY:

Insufficient air for

combustion

• Air tight house.

• A vacuum in room due to

other air-moving device.

• Supply make up air to the unit.