Using LANVIEW

SecureStack A2 PoE Installation Guide 4-3

Note: The terms flashing, blinking, and solid used in

Table 4-1

indicate the following:

Flashing: LED is flashing randomly.

Blinking: LED is flashing at a steady rate (approximately 50% on, 50% off).

Solid: LED is on steady and not pulsing.

Table 4-1 LANVIEW LEDs

LED

Color

State

Recommended Action

CPU

Off

Power disconnected.

If the LED remains off after connecting AC
power or DC power from an RPS, check
the following:
1. Make sure there is power at the power

source (AC source and RPS if
applicable).

2. Replace the power cord with a known

good one or check the continuity of the
power cord.

3. If the SecureStack A2 still does not

power up, the system may have a fatal
error. Contact Enterasys Networks for
technical support.

Red

Solid. Boot-up failed.

If the LED remains red for several
minutes, the system may have a fatal
error. Contact Enterasys Networks for
technical support.

Blinking. Diagnostics have
failed.

Contact Enterasys Networks for technical
support.

Amber

Solid. Diagnostics are running. If the LED remains amber for more than

several minutes, contact
Enterasys Networks for technical support.

Blinking. Code image is being
downloaded.
This also notes when the
configuration is being saved to
member units. (This occurs
every 15 minutes and when the
user enters the “save config”
command).

None.

Green

Solid. System is fully
functional.

None.

Blinking. Boot-up in process.

None.