Model No. FAW-55 may be vented as shown. The vent cap must

be at least 12 feet (3.7m) above the floor. Clearance to combustible

construction is held by the fixed spacers at 1 inch (25mm) with B-1

vent pipe. Installation must conform to local codes.
4” (102mm) Round (all parts purchase locally except item 2)

1. Type B-1 round pipe

2. Part No. DV-648, 4” (102mm) oval-to-round flue adapter

kit (see accessories)

3. Single story type B-1 gas vents require a baseplate and one

pair of ceiling plate spacers.

4. Multi-story type B-1 gas vents require a baseplate, one pair

of ceiling plate spacers at the first floor ceiling and one pair

of fire stop spacers at each successive ceiling level.

4” (102mm) Oval (all parts purchase locally)

1. Type B-1 oval pipe

2. Single story type B-1 gas vents require a baseplate and one

pair of ceiling plate spacers.

3. Multi-story type B-1 gas vents require a baseplate, one pair

of ceiling plate spacers at the first floor ceiling and one pair

of fire stop spacers at each successive ceiling level.

4” (102mm) Oval In-The-Wall (all parts purchase locally)

1. Type B-1 oval pipe

2. Type B-1 oval elbows

3. Single story type B-1 gas vents require a baseplate and one

pair of ceiling plate spacers.

4. Multi-story type B-1 gas vents require a baseplate, one pair

of ceiling plate spacers at the first floor ceiling and one pair

of fire stop spacers at each successive ceiling level.

Stud space around gas vents must be free of obstructions and

building paper.

Use U.L. listed gas vent equipment when installing the FAW-55.

For vent pipe running through walls, roof, and within one inch

(25mm) of combustible construction, use B-1 (one inch (25mm)

clearance to combustibles) vent pipe. Type B-2 x 4 or Type B-2 x

6 are to be used in conjunction with a Listed fire stop spacer.
Type BW gas vent pipe is available for single story or multi-story

installations. Type BW gas vent pipe is to be used with the Listed

base plate, ceiling plate spacers and fire stop spacers.

VENT

ENCLOSURE

(not shown)

ADAPTER

BRACKET

SIDE

FRONT

SIDE

FRONT

SPACER

48 ELBOWS

4” (102MM) OVAL STD.

o

BASEPLATE

FRONT

SIDE

BASEPLATE

Accessories

Part No.

Description

SOR-1

Register, side outlet, fixed register

SOK-1

Side outlet, 10” (254mm) maximum extension,

fixed register

ROK-1

Rear Outlet, 10” (254mm) maximum extension,

adjustable register

DV-651

Vent enclosure, 14” (356mm) [for room up to 96

1/2” (245cm) in height]

DV-665

Vent enclosure, 24” (610mm) [for rooms up to

106 1/2” (270.5cm) in height]

DV-666

Vent enclosure, 36” (914mm) [for rooms up to

118 1/2” (301cm) in height]

DV-648

4” (102mm) Oval-to-Round flue adapter kit