Installation – Empire Products FAW-55IP User Manual

Page 6

Advertising
background image

12429-10-0408

Page 6

Figure 2

Figure 3 Figure 3A

VENT CENTER TO COMBUSTIBLES
MINIMUM CLEARANCE 9/16” (40mm)

4”(102mm) OVAL TYPE “B”
CONNECTION

7/1/2” (191mm) MINIMUM

CLEARANCE TOP TO

COMBUSTIBLES

VENT ENCLOSURE

DV-651 or DV-665 or

DV-666

MINIMUM CLEARANCE

TO COMBUSTIBLES

18”(457mm)

SIDE OUTLET

KIT PART SOK-1

Register
Part SOR-1

6 5/8 (168mm)

WALL TO VALVE INLET

3”(76mm) TO CENTER OF
½”(13mm) INLET ELBOW

3 3/4”(95mm) FLOOR TO
CONTROL VALVE INLET

4”(102mm) MINIMUM
CLEARANCE TO
COMBUSTIBLES

REAR OUTLET

REGISTER KIT #ROK-1

Installing Optional Rear Outlet

Rear outlet kit, 10” (254mm) boot assembly with register, ROK-1

for warm air discharge into an adjoining room.
Attention: Before furnace is attached to the wall, the wall opening

for the rear outlet must be cut, in addition to removal of the outer

and inner casing knockouts on furnace.
1. The wall opening measurements for the rear outlet are the

following.

A. From floor to bottom of wall opening is 14 3/4”

(375mm).

B. From bottom of wall opening to top of wall opening is 8

1/2” (216mm) .

C. Wall opening width is 12 1/8” (308mm).

2. Remove outer casing knockout from outer casing back.

3. Remove inner casing knockout from inner casing.

4. Attach furnace to wall (see Attaching Furnace to Wall).

5. Align clearance holes on 8” x 12” (203mm x 305mm) boot with

screw holes on outer casing back and mark boot to be flush

with wall surface. Remove boot and cut to proper length.

6. Attach 8” x 12” (203mm x 305mm) boot to outer casing back

with (6) #10 x 1/2” (13mm) screws provided.

7. Align clearance holes on 6” x 10” (152mm x 254mm) duct with

screw holes on inner casing and mark duct to be 2 1/4” (57mm)

shorter than 8” x 12” (203mm x 305mm) boot. Remove duct

and cut to proper length.

8. Attach 6” x 10” (152mm x 254mm) duct to inner casing with

(6) #10 x 1/2” (13mm) screws provided.

9. Insert rear register into 8” x 12” (203mm x 305mm) boot.

Attach rear register to wall with (2) #10 x 1” (25mm) screws

provided.

Figure 1

ALL CONNECTIONS MUST BE MECHANICALLY

MADE AND LISTED CLERANCES MAINTAINED

*PARTS LISTED ARE TO BE PURCHASED

LOCALLY

SPACER STRAP*

BASE PLATE*

MOUNTING HOLE

2 PIECE VENT ENCLOSURE

CUT TO THE PROPER LENGTH

BASE PLATE

GASKET

(140mm)

(406mm)

(102mm)

(102mm)

(140mm)

(102mm)

3 1/4” (83mm)
11 ½”(292mm)

INSTALLATION