Inside vertical installations, Outside vertical installations, Installation – Enviro C-10985 User Manual

Page 13

Advertising
background image

� ��

���� ���

���� ��� ������� ��� ��

�� ����� ��� ����� ���

���� �� ��� ������ ������

���� ��������

���� ������

���� ���� ����

������� ������

������� �����

�������� ���� ����

����� ��� ��� ����

���� �������

����� ��� ���� �������� ����
�������� � ������ ���� ���
���������� �� �������������

Figure 15: Inside Vertical Installation.

1. Choose a stove location that is ideal. See the

section “D

ECIDING

W

HERE

TO

L

OCATE

YOUR

P

ELLET

A

PPLIANCE

.”

2. Place a non-combustible hearth pad where

necessary.

3. Place the unit on the hearth pad (if installed

on a combustible surface) and space the

unit in a manner so when the pellet vent is

installed vertically, it will be 3” (7.5 cm) away

from a combustible wall.

4. Install the tee with clean out.
5.

I

nstall the pellet vent upward from there.

When you reach the ceiling, make sure

that the vent goes through the ceiling fire

stop. Maintain a 3” (7.5 cm) distance to

combustibles and keep attic insulation away

from the vent pipe. Maintain an effective

vapor barrier.

6. Finally, extend the pellet vent to go through

the roof flashing.

7. Ensure that the rain cap is approximately 24”

(600 mm) above the roof.

To accomplish a outside vertical pipe installation,

follow steps 1 through 5 in the “I

NSIDE

V

ERTICAL

I

NSTALLATIONS

- F

REESTANDING

” section and then finish it

by performing the following (refer to Figure 16).

1. Install a tee with clean out on the outside of the

house.

2. Install PL vent upward from the tee. Make sure

that you install support brackets to keep the vent

straight and secure.

3. Install ceiling thimble and secure the flashing as

you go through the roof.

4. Ensure that the rain cap is approximately 24”

(600 mm) above the roof.

13

Installation

I

NSIDE

V

ERTICAL

I

NSTALLATIONS

:

Figure 16: Outside Vertical Installation.

O

UTSIDE

V

ERTICAL

I

NSTALLATIONS

:

Rain cap

Flashing

24"

(61 cm)

4"

(10 cm)

Tee with

cleanout

3" (7.5 cm)

Clearance

Support

bracket

Type "PL"

vent

Advertising