Clearances to combustibles, Alcove clearances, Installation – Enviro C-10985 User Manual

Page 7

Advertising
background image

7

Installation

C

LEARANCES

TO

C

OMBUSTIBLES

:

IMPORTANT: Attach the Mini’s Hearth Pad when installing the unit on a combustible floor. The supplied

hearth pad meet all the requirement of a proper hearth pad. If you do not use the supplied hearth pad a

hearth pad must be used when on combustible material.

A

LCOVE

C

LEARANCES

:

This unit may be installed in an alcove. Maintain these clearances to combustibles.

Minimum Alcove width

36 inches (91.5 cm)

Minimum Alcove height 48 inches (122 cm)

Maximum Alcove depth 30 inches (76 cm)

Install vent at clearances specified by

the vent manufacturer.

S

id

e

W

al

l

Back Wall

Adja

cen

t W

all

8"

(20cm)

3"

(7.5cm)

4" (10cm)

36"

(91.5cm)

30"

(76cm)

48"

(122cm)

If the Mini is installed on carpet the use of a solid

material must be used under leveling legs.

These dimensions are minimum clearances but

it is recommended that you ensure sufficient

room for servicing, routine cleaning and

maintenance.

Side wall to unit 8 inches (20 cm)

Back wall to unit 4 inches (10 cm)

Corner to unit

3 inches (7.5 cm)

Figure 4: Mini Clearance to Combustibles.

Figure 5: Mini Minimum Alcove Size.

Advertising