1. installing welding generator, 2. connecting the battery – Hobart Welding Products CONTRACTOR 3225D User Manual
Page 18
OM-480 Page 14
SECTION 4 – INSTALLATION
4-1.
Installing Welding Generator
install1 12/99 – Ref. ST-800 652 / Ref. ST-800 477-A / ST-158 936-A / S-0854
1
2
Electrically bond generator frame to
vehicle frame by metal-to-metal
contact.
GND/PE
3
4
Y
Always ground generator
frame to vehicle frame to pre-
vent electric shock and static
electricity hazards.
1
Generator Base
2
Metal Vehicle Frame
3
Equipment Grounding
Terminal
4
Grounding Cable
Use #10 AWG or larger insulated
copper wire.
Y
If unit does not have GFCI re-
ceptacles, use GFCI-
protected extension cord.
2
OR
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
OR
Movement
Airflow Clearance
Location
Grounding
OR
Y
Do Not Lift Unit From End
4-2.
Connecting The Battery
ST-156 011-A / Ref. ST-188 448 / S-0756
1/2 in
+
–
Y
Connect Negative (–)
Cable Last.
Tools Needed: