OM-480 Page 16

ether1 12/96 – ST-153 382-A / Ref. ST-188 448

Y

Stop engine.

Y

Improper handling or expo-
sure to ether can harm your
health. Follow manufactur-
er’s safety instructions on
cylinder.

Y

Do not use Ether Starting Aid
while engine is running.

Open side door(s).

1

Ether Cylinder

2

Nozzle

Remove cover and clean cylinder
nozzle.

3

Clamp

4

Fitting

5

Cap

6

Valve

Remove cap and clean fitting.
Install cylinder on fitting. Tighten
clamp.

.

After installing cylinder, wait at
least 10 minutes before using
to let ether particles settle and
prevent atomizer plugging.

Put cap on fitting when cylinder is
removed.

1

2

3

4

6

5

4-5.

Installing Ether Cylinder (Optional Ether Starting Aid)

Ref. ST-800 162-A

Open left side door.

1

Bracket

Route cables through bracket.

2

Positive (+) Weld Output
Terminal

3

Negative (–) Weld Output Ter-
minal

For Stick welding Direct Current
Electrode Positive (DCEP), con-
nect work cable to (–) terminal and
electrode holder cable to (+)
terminal.

For Direct Current Electrode Nega-
tive (DCEN), reverse cable
connections.

If equipped with optional polarity
switch, connect electrode holder
cable to Electrode (–) terminal and
work cable to Work (+) terminal.

For FCAW welding, connect work
cable to (–) terminal and wire feeder
cable to (+) terminal.

Close door.

Tools Needed:

4-6.

Connecting To Weld Output Terminals