HP 16500C User Manual

Page 23

Advertising
background image

To trigger after all status bus lines finish transitioning

In some applications, you will want to trigger a measurement when a
particular pattern has become stable. For example, you might want to trigger
the analyzer when a microprocessor’s status bus has become stable during
the bus cycle.

1

Select the timing analyzer Trigger menu and define a term called
PATTERN to represent the value to be found on the label
representing the status bus lines.

2

Under Timing Sequence Levels, enter the following sequence
specification:

TRIGGER on “PATTERN” > 40 ns

Triggering after lines are done transitioning

Triggering

To trigger after all status bus lines finish transitioning

1–13