Termination locations, A. appliance opening minimum clearances – Hearth and Home Technologies TWILIGHT-II-B User Manual

Page 20

Advertising
background image

Outdoor Lifestyles by Hearth & Home Technologies, Inc. • Twilight-II-B • 2108-900 Rev. Z • 9/12

20

6

6

Termination Locations

D

E

L

FP

A

H

M

X

J or K

I

A

G

F

FP

FP

FP

FP

FP

B

B

B

FP

= APPLIANCE OPENING

X

= AIR SUPPLY INLET

= AREA WHERE APPLIANCE IS NOT PERMITTED

J

= 9 in. (U.S.A.)

12 in. (Canada) .......clearance to non-mechani-

cal air supply inlet to building
or the combustion air inlet to
any other appliance

K

= 3 ft. (U.S.A.)

6 ft. (Canada) ...........clearance to a mechanical

air supply inlet

L** = 54

in.

.......................clearance

above

paved

side-

walk or a paved driveway lo-
cated on public property

M*** = 35-5/16

in.

...............clearance under veranda,

porch, deck, balcony or over-
hang

64-5/16 in. ..............vinyl

N

= 12 in. ......................non-vinyl siding

36 in. ......................vinyl siding

P =

8

ft.

(See Note 1)

(See Note 1)

(See Note 2)

*

36 in. minimum for vinyl windows or vinyl siding.

**

a appliance shall not open directly above a sidewalk or paved
driveway which is located between two single family dwellings
and serves both dwellings.

*** only permitted if veranda, porch, deck or balcony is fully open

on a minimum of 2 sides beneath the fl oor, or if the screened
porch guidelines are followed.

NOTE 1: Local codes or regulations may require different clear-
ances.

NOTE 2: Termination in an alcove space (spaces open only on
one side and with an overhang) are permitted with the dimensions
specifi ed for vinyl or non-vinyl siding and soffi ts. 1. There must be 3
feet minimum between terminations or between the appliance and
termination. 2. All mechanical air intakes within 10 feet of a termi-
nation must be a minimum of 3 feet below the appliance hood. 3.
All gravity air intakes within 3 feet of the appliance hood must be a
minimum of 1 foot below the termination.

This appliance is approved for installation onto screened porches
with the following guidelines:

Figure 6.1 Minimum Clearances for Appliance Opening

NOTE: There may be some odor and small amounts of soot
associated with venting the Twilight-II-B onto a screened
porch. Ensuring good cross draft ventilation and routine
maintenance of the appliance will maximize comfort and
cleanliness.

Minimum porch area: 96 square feet
Minimum ceiling height: 92 inches
Minimum two walls must be screened
Minimum top of screen height, side walls: 6 ft. 8 in.
Minimum screen area: 64 square feet

A. Appliance Opening Minimum Clearances

M

N

P

R

Q

FP

A

= 0 in ........................clearances above grade, veran-

da, porch, deck or balcony

B*

= 12 in. .....................clearances to window or door

that may be opened, or to per-
manently closed window.

D

= 35-5/16 in. (

non-vinyl)

64-5/16

in.

(vinyl)

......vertical clearance to ventilated

soffi t located above the hood
within a horizontal distance of 2
feet (60 cm) from the center-line
of the hood

E =

35-5/16

in.

(non-vinyl)

64-5/16

in.

(vinyl)

.. ....clearance to unventilated soffi t

F

= 9 in. ......................clearance to outside corner

G*

= 12 in ......................clearance to inside corner

H

= 3 ft. (Canada) ........not to be installed above a gas

meter/regulator assembly within
3 feet (90 cm) horizontally from
the center-line of the regulator

I

= 3 ft.

........................clearance to service regulator

vent outlet and electric service

Advertising