Hearth and Home Technologies TWILIGHT-II-B User Manual

Page 32

Advertising
background image

Outdoor Lifestyles by Hearth & Home Technologies, Inc. • Twilight-II-B • 2108-900 Rev. Z • 9/12

32

APPLIANCE

HOOD

TOP OF

APPLIANCE

SOFFIT

SIDING

HOUSEWRAP (BUILDING

PAPER) AND SHEATHING

35-5/16 in.

MINIMUM CLEARANCE

TO NON-VINYL

64-5/16 in.

CLEARANCE TO VINYL

SOFFIT, OVERHANG, MANTEL,

OR CEILING

12 in.

MINIMUM CLEARANCE

TO NON-VINYL SIDING

36 in. MINIMUM

CLEARANCE TO VINYL SIDING

DRAIN PLANE

DETERMINED BY

LOCAL CODE

BRICK OR OTHER NON-COMBUSTIBLE

FACING MATERIAL 6 INCH MAXIMUM

PROJECTION FROM SURFACE OF

FIREPLACE (INCLUDES NON-COMBUSTIBLE

MANTEL PROJECTION)

NON-COMBUSTIBLE BRICK LEDGE

MUST BE TIGHT TO APPLIANCE

FACE OR NON-COMBUSTIBLE SHEATHING

TOP OF HOOD

INSULATION

Figure 10.7 Exterior View with Non-combustible Facing Material

Figure 10.6 Exterior View

DETAIL -

SEE FIGURE 10.5

NOTE: All fi nishing materials on top of exterior
sheathing must be non-combustible for a minimum
of 10-7/8 inches above and on both sides of
the exterior face of the appliance. This non-
combustible fi nishing material can be up to a
maximum of 6 inches thick (6 inches maximum
horizontal overhang) to allow for brick and stone
alcoves (see Figure 8.5).

NOTE: Combustible housewrap or building
paper MUST NOT extend over the outside of
non-combustible sheathing, and MAY extend
over the fl ashing header behind non-combustible
sheathing. Use high temp caulk to seal between
combustible sheathing housewrap and non-
combustible sheathing.

APPLIANCE

HOOD

TOP HOOD

TOP OF

FIREPLACE

10-7/8 in.

CEILING OR OVERHANG

64-5/16 in.

MINIMUM CLEARANCE

TO VINYL SOFFIT,

CEILING OR OVERHANG.

35-5/16 in.

MINIMUM CLEARANCE TO

NON-VINYL SOFFIT, MANTEL,

CEILING OR OVERHANG.

STUD WALL

SOFFIT

HOUSEWRAP

INSULATION

HOUSEWRAP
(BUILDING
PAPER) OVERLAP
FLASHING 1 in.

SHEATHING,

COMBUSTIBLE

FIREPLACE

HEADER

INSULATED

FRAMING

STANDOFF

NON-COMBUSTIBLE

SHEATHING

FLASHING

HEADER

Advertising