D. optional accessories – Hearth and Home Technologies TWILIGHT-II-B User Manual

Page 28

Advertising
background image

Outdoor Lifestyles by Hearth & Home Technologies, Inc. • Twilight-II-B • 2108-900 Rev. Z • 9/12

28

Figure 9.3 Fan Wiring Diagram

D. Optional Accessories

Optional fan and remote control kits require that 110-120
VAC be wired to the factory installed junction box before
the appliance is permanently installed (see Figure 9.3).

Fan Installation

To provide best airfl ow, we recommend positioning fan
on the left side (as viewed from appliance interior side
(see Figure 9.2). NOTE: It is recommended fan be in-
stalled prior to gas line installation.

Wall Switch

Position the wall switch in the desired position on a wall.
Run a maximum of 25 feet (7.8 m) or less length of 18
A.W.G. minimum wire and connect it to the appliance ON/
OFF switch pigtails.

NOTE: If any of the original wire as supplied
with the appliance must be replaced, it must be
replaced with the type 105

o

C rated wire.

Figure 9.2 Fan location

FAN

DRIP
TRAY

SEE DETAIL A

WIRE LEAD

2 FEMALE ENDS

PLUG AND WIRE

ASSEMBLY

JUNCTION BOX

6 FT.

APPROX.

TEMPERATURE
SENSOR SWITCH

FAN SPEED
CONTROL

(RHEOSTAT)

DETAIL A

WIRE LEAD

1 MALE END
1 FEMALE END

6 FT.

APPROX.

FAN KIT

#GFK-160T

APPLIANCE

INTERIOR

SIDE

Advertising