Safety functions, Operating a safety circuit – Hyundai HX300L User Manual

Page 32

Advertising
background image


HX200/HX200L-2000/HX300/HX300L/HX400



1-24


1.10. Safety Functions

1.10.1. Operating a Safety Circuit

E

M

1

A

S

G

1

TP

EN1

L

S

1

Man1

Auto1

M

O

T

O

R

P

O

E

R

O

N

M

S

H

P

1

Contactor MSHP1

M

Drive

Unit

Computer

Commands

Operating

mode selector

LS

Limit switch

ASG

AUTO Mode Safeguard

GSG General Safeguard
TP EN

Enabling device in T/P

EM

Emergency stop switch

&

M

S

H

P

2

Contactor MSHP2

&

TP

EN2

Man2

Auto2

+

Operating

mode selector

+

E

M

2

A

S

G

2

L

S

2

Interlocking

G

S

G

2

G

S

G

1

Fig 1.5 Robot’s Safety Circuit

The robot's safety system is based on a two-channel safety circuit that is
continuously monitored. If an error is detected, the power supply to the motors is
disconnected and the motor brake is applied. To return the robot to MOTORS ON
mode, the switches of two-channel circuit must be connected. If one of the
two-channel circuit switches shorts, the contactor of motor will be disconnected
leading to the application of brake, and finally the robot will be stopped. Furthermore,
when safety circuit is disconnected, the interrupting call will be sent automatically to
the controller to find out the possible reason for the interruption.

The safety control circuit of operation is based on dual safety electric circuit in which
the controller and MOTORS ON mode are operated inteactively. In order to be in
MOTORS ON mode, the safety circuit consisted of several swtiches must be all
connected. MOTORS ON mode indicates that drive power is supplied to the motors.
If one of the contactors is disconnected, the robot will always return to MOTORS
OFF mode.