1.5 Specifications, water

1.5.1

Specifications, soft water

Value

Parameters

Drinking water, cold

Type

2–6 bar/200–600 kPa

Supply pressure

< 1.5 mmol/l, < 5 °dH (soft water)

Hardness

¾" outside thread

Thread

DN 15 hose with ¾" union nut

Connection

Table 12: Specifications, soft water

1.5.2

Specifications, hard water

Value

Parameters

Drinking water, cold

Type

Up to 50 °C (122 °F)

Temperature

2–6 bar/200–600 kPa

Supply pressure

0–4 mmol/l, 0–25 °dH

Hardness

¾" outside thread

Thread

DN 15 hose with ¾" union nut

Connection

Table 13: Specifications, hard water

1.5.3

Specifications, waste water

Value

Parameters

Up to 80 °C (176 °F)

For adjusting the waster water temper-
ature, see chapter “Standard settings”
in the operating manual.

Temperature

DN 40 direct connection

Connection

Table 14: Specifications, waste water

1.6 Specifications, power supply

Size

Parameters

605

610

IP X5

Protection type

3 PE / AC 50/60 Hz

3 NPE / AC 50/60 Hz

Mains type

208

Voltage (V)

5,1

7,4

Connected load (kW)

16

25

Fuses (A)

13