The unit is delivered without a power cable and with a three-phase terminal
connection.

1.

Prepare the connection cable (cable type H07RN-F compliant with
EN-Norm).

2.

Remove the back panel.

3.

Pass the connection cable through the strain relief screws into the
unit.

4.

Tighten the strain-relief screws securely so that the power cable
cannot be pulled out.

5.

Connect the power cable to the terminals.

6.

Remount the back panel.

4.3.2

Single-phase power connection (only SpaceSaver)

The unit is delivered without a power cable and with a three-phase terminal
connection.

NOTICE

Size 605 units in the 380 V, 400 V and 415 V versions can also be
single-phase connected.

The unit's connected output is reduced with a single-phase connection
(see

Chapter “Specifications, power supply”, Page 13

).