Mounting and wiring the control 2-11, Powerline carrier devices, Figure 14. psc04 powerline interface connections – Honeywell VISTA-20P User Manual

Page 17

Advertising
background image

Connecting Relay Modules, Powerline Carrier Devices and Output Triggers

4204/4229 Relay Modules


UL

For UL installation

requirements, refer to the
Installation Instructions for
the 4204.

1. Mount either remotely or in the control panel.
2. Connect each module to the control’s keypad terminals and set the device addresses

as previously described in the Connecting Keypads and Other Addressable
Device
section. Use the connector harness supplied with the module. Use standard
4-conductor twisted cable for long wiring runs.

VISTA-20P: Up to 16 relays (if no powerline carrier devices are used)

VISTA-15P: Up to 8 relays (if no powerline carrier devices are used)

3. Connect the desired field wiring to the unit's relay contact terminals.

TB2

12

11

10

9

8

7

6

5

4

3

2

1

(–) GROUND

(+) 12V

YEL

BLK

GRN

RED

13

14

15

16

DIP SWITCH
FOR SETTING DEVICE ADDRESS
AND ENABLING/DISABLING TAMPER

COVER TAMPER (REED) SWITCH

TB1

4204

4-PIN TOUCHPAD PLUG

3

2

RELAY

1

4

TYPICAL

(SHOWN "OFF")

C

NC

NO

C

NC

NO

C

NC

4204_conn-1-V0

NC

NO

C

NC

NO

EITHER OR BOTH
CAN BE USED

DATA IN
FROM CONTROL

DATA OUT
TO CONTROL

RELAY

RELAY

RELAY

Figure 13. 4204 Connections to Control

• Supervision: 4204 and 4229 modules are supervised against removal. The module’s

device address is displayed as follows if a module is disconnected from the control’s
terminals, or if the module cover is removed and the tamper jumper is installed:

Alpha: CHECK xx Wire Expansion

FAULT xx Wire Expansion

ALARM xx Wire Expansion

Fixed-Glass: lxx (or 91 if field *199 set for 2-digit display)

where “xx is the module’s address.
• If communication/tamper failure occurs on a device with zones wired to it, all zones on

the device will be displayed in their respective partitions.

Powerline Carrier
Devices

UL

Powerline Carrier

devices and the 1361X10
Transformer are not UL
Listed for fire or burglary
functions and are intended
for home automation.

1. Install the powerline carrier devices according to the instructions included with each.

VISTA-20P: Up to 16 devices (if no relays are used)

VISTA-15P: Up to 8 devices (if no relays are used)

2. Use Programming Mode to enter the device house ID in data field*27, and enter the

unit code using *79 Output Device menu Mode.

3. See connections diagram in the AC Wiring section for connecting the 1361X10

transformer to the triggers.

• You must use a 1361X10 Transformer instead of the 1321 Transformer.

• The 1361X10 Transformer provides AC power to the control panel, and also supplies

signals from the control panel through the premises AC wiring to the Powerline
Carrier devices (which are plugged into AC outlets). You can then make devices that
are plugged into Powerline Carrier devices perform various functions in response to
commands you enter at the security system keypads.

Canada: Use the PSC04 Powerline Interface as shown below.

1 2 3 4

SA4120XM-1 CABLE

X-10 PSC04

POWERLINE INTERFACE

YEL

RED

GRN

BLK

MODULAR PHONE CORD (not supplied)
1 - BLACK
2 - RED
3 - GREEN
4 - YELLOW

SYNC

DATA

COM

1

3

4

5

6

7

8

KEY

+12 A

UX.

D

ATA

COM

SYNC

GND (-)

OUTPUT 17

(RED)

OUTPUT 18

(GREEN)

(ORANGE)

(YELLO

W)

(BLUE)

(PURPLE)

(BLA

CK)

8-PIN TRIGGER CONNECTOR

Figure 14. PSC04 Powerline Interface Connections

Mounting and Wiring the Control

2-11