Features and Installation Highlights

This manual applies to the following Honeywell security systems:
ADEMCO VISTA-20P/ADEMCO VISTA-20PSIA/ADEMCO VISTA-20PCN (collectively referred to as
VISTA-20P series), ADEMCO VISTA-15P/ADEMCO VISTA-15PSIA/ADEMCO VISTA-15PCN
(collectively referred to as VISTA-15P series)
Features and procedures apply to all, except where differences are noted.

SIA Installations: The VISTA-20PSIA and VISTA-15PSIA are certified SIA-compliant controls that
meet SIA specifications for False Alarm Reduction. The other controls described in this manual are
not certified as SIA compliant, but can be programmed for False Alarm Reduction. To program for
False Alarm Reduction, follow the SIA Guidelines noted in the applicable programming fields.

NOTE: Throughout this manual, device model numbers are ADEMCO model numbers

unless otherwise noted.

Capabilities and Functions

Feature/Function

ADEMCO VISTA-20P Series

ADEMCO VISTA-15P Series

Partitions

• 2 partitions, can protect two independent

areas

• Common zone option allows either

partition to arm, while leaving a common
area (ex. lobby or foyer) disarmed for
access into the other partition.

VISTA-15P is not a partitioned system.

Zones

Up to 48 protection zones plus 16 keyfob
zones (zones 49-64) for total of 64 zones:

• 8 basic hardwired zones (zones 1-8) with

optional zone-doubling feature

• Up to 40 additional wired zones (zones 9-

48) using up to 5 4219/4229 modules

• Up to 40 wireless transmitter zones (5800

series; zones 9-48)

• Up to 4 configurable zone types

Up to 32 zones plus 8 keyfob zones (zones
49-56) for total of 40 zones:
• 6 basic hardwired zones (zone 1-6)

• Up to 16 additional wired zones (zones 9-

24) using up to 2 4219/4229 modules

• Up to 26 wireless transmitter zones

(5800 series; zones 9-34)

• Up to 2 configurable zone types

Security Codes

Up to 48 Security Codes, with separate
authority levels and partition access

Up to 32 Security Codes, with separate
authority levels

One-button arming

Dedicated keys can arm the system.

Dedicated keys can arm the system.

Schedules

Up to 32; can control devices and/or auto-
arm/disarm

Up to 8; can control devices and/or auto-
arm/disarm

Keypad macros

Up to 4; activated by wired keypads

Up to 2; activated by wired keypads

Paging

Up to 4 pagers; certain system conditions
can report to pagers; can use a dedicated
key on keypads to send a signal to a pager

Up to 2 pagers; certain system conditions
can report to pagers; can use a dedicated
key on keypads to send a signal to a pager

Event Logging

100 events; log display is done via Ademco
Compass Downloader software or
installer/master code at Keypad

50 events; log display is done via Ademco
Compass Downloader software or
installer/master code at Keypad

Zone descriptors

Can assign for all zones (for alpha display keypads and/or 4285/4286 Phone Module).

Bell supervision

Optional, detects external sounder wiring short or open; causes a trouble condition,
keypad display, and sends a report to the central monitoring station, if enabled.

RF jam detection

Optional, for wireless systems detects a condition that may impede proper RF reception
(i.e., jamming or other RF interference); causes keypad display, and sends a report to the
central monitoring station (if trouble reporting is enabled).

Telephone Line
Monitoring

Built-in option can monitor the telephone line voltage and can cause a local display, or a
display and trouble/alarm sound

Downloading

Via an IBM compatible computer, Compass downloading software, and a compatible
HAYES or CIA modem specified by Ademco.