Operation – Harman Stove Company SF160 User Manual

Page 10

Advertising
background image

10

3-90-70742R11_05/13

Operation

Automatic Draft Control
The heat output is regulated by the automatic draft control

on the bottom door. The electric motor (a) opens and closes

the flapper door (B). Opening and closing the flapper door

regulates the air flow into the firebox.
The maximum air flow can be adjusted by turning the

adjusting bolt (C). Turn counter-clockwise for more air, and

clockwise for less air. adjust this bolt only while the flapper

door is in the closed position. Otherwise, motor damage

could occur.
The idle air adjuster (D) controls the minimum amount of air

that enters the firebox. adjustment is made by turning the

adjuster vertical for zero idle air, or horizontal for maximum

idle air. It is best to start out with a medium setting as shown

in figure 9.

FIG. 9

Starting a Wood Fire
Make sure the boiler and all piping is full of water and that

all air has been purged from the system.
Never start a fire without water in the system. An

explosion will occur.
Turn on electrical power to the boiler. This should cause the

automatic draft control to open.
Open the ash pan door to allow free air movement. With

the firebox door open, crumble approximately 8 sheets

of newspaper and place on the grates. lay some small

kindling on top of the newspaper. Be sure this kindling is

dry and no more than 3/4 in. in diameter. layer the kindling

in a crisscross type pattern, to allow maximum air flow.

next lay some larger pieces of wood on top of the kindling

(approximately 2 in. diameter). Using a match or lighter, light

the paper just inside the door. Close and latch the firebox

door and allow the fire to burn a few minutes. after about

five minutes, close the ash pan door and re-open the firebox

door an inch or two, to allow the smoke to clear. add 4 or 5

larger logs (about 4 in. diameter) to the well established fire

and close the firebox door. leave the ash pan door open for

about five minutes only. now open the firebox door using

the same method as before, always closing the ash pan

door before opening the firebox door. now you can load the

firebox to the desired level. You may load wood to the top of

the firebox. Close and latch the door. The ash pan door may

again be opened to speed the ignition process.
Do not leave the boiler unattended with any door open.
after the wood is burning well, close the ash pan door. The

automatic draft control will now regulate the fire, based on

temperature demand.
The idle air adjuster must be tuned to where the fire doesn’t

go out during long periods with no demand. Experience

will dictate the best setting for your installation. normally,

the two manual draft controls on the firebox door are kept

closed while burning wood.