3 feet (0.9m) above the point at which they exit from the

roof, it must also extend 2 feet (0.6m) above the highest

point within a 10 ft. (3m) radius.

limit connector pipe to 8 ft. or less, with no more than two

elbows. all horizontal sections should have 1/4 in. rise per

foot. The chimney must be capable of providing a draft

reading of at least .06 in. of water column. a barometric

damper can be installed to prevent excessive and erratic

draft. all connector pipe should be secured with sheet metal

screws at each joint.

Installation

Plumbing
The Harman® Trident Boiler can be used as a “stand alone”

boiler or as an add-on to an existing hot water heating

system.
The diagrams in this manual are meant to show the

necessary equipment and piping. Your system may look

very different. However, if configured properly, the same

results will be achieved.
fig. 6 shows a typical plumbing diagram for tying into an

existing system. This method provides water circulation

between the two boilers with a circulating pump. In this

setup, the domestic water coil in the existing boiler will be

heated, making it unnecessary to install a water coil in the

Trident Boiler.
Tying-in to an existing boiler must be done in the return line

between the circulator and the existing boiler. Run a pipe

from there to a small circulator, and then into the 1-1/4 in.

fitting on the rear of the Trident Boiler. next run a pipe from

the 1-1/4 in. fitting on the top of the Trident Boiler to a Tee

fitting in the supply line of the existing boiler. This Tee fitting

must be installed between the existing boiler and the flow

Control Valve, as shown in fig. 6. an air valve should be

installed on this line.

FIG. 5

Air Valve

Notice:

The Aquastat controls supplied with the Trident Boiler

are designed only to maintain water temperature

within the boiler. The actual heating system is

controlled separately by your thermostat(s) opening

zone valves or energizing circulation pump(s).
Do not attach a thermostat to the supplied controls.

NOTE: The restriction of not venting more than one appliance

to the same flue applies to the U.S. specifically. In Canada,

Csa B365-01 allows it, with specific restrictions. Be sure to

contact your building code inspection official to see if this

option is allowed in your area, and to find out the specific

requirements for such an installation.

DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE

THAT IS SERVING ANOTHER APPLIANCE.