Heat & Glo Fireplace Heat-N-Glo 6000XLT-CDN User Manual

Page 24

Advertising
background image

24

TRIM HEAT

SHIELD IF TOO

LONG, ADD TO

SHIELD IF TOO

SHORT

EXTERIOR

FIRESTOP

INTERIOR

FIRESTOP

HEAT SHIELD

Figure 20. 12" x 12" Hole and Vent Pipe

2. Position the

firestops.

3. Place the heat

shield to the top.

4. Continue the vent

run.

Figure 21. Heat Shield, Interior & Exterior Firestops
For Vertical Runs -
One ceiling firestop is

REQUIRED at the hole in each ceiling through

which the vent passes.
To install firestops for vertical runs that pass through

ceilings:
• Position a plumb bob directly over the center of

the vertical vent component.

• Mark the ceiling to establish the centerpoint of the

vent.

• Position the firestops on both sides of the hole

previously cut and secure the firestops with nails or

screws.

• The heat shields of the firestops MUST BE placed

towards the top of the hole.

• Continue the vent run through the firestops.

1. Cut the 12-inch by

12-inch hole.

Advertising
This manual is related to the following products: