5700 act wood stove, Building a fire, Operating instructions (cont’d) – Hearth and Home Technologies 820-0721 User Manual

Page 20

Advertising
background image

5700 ACT Wood Stove

Page 20

September 1, 2008

R

250-7090e

NOTE:

These are approximate settings, and will vary with type of wood or chimney draft. Due to altitude and other environmental circumstances, this

operation information is a guideline only. Similar burn rates may be obtained using other settings unique to your situation.

There are many ways to build a fire. The basic principle is to light easily-ignitable tinder or paper, which ignites the fast

burning kindling, which in turn ignites the slow-burning firewood. Here is one method that works well:

1

. Place several wads of crushed paper on the firebox floor. Heating the flue with slightly crumpled newspaper before

adding kindling keeps smoke to a minimum.

2. Lay small dry sticks of kindling on top of the paper.

3. Open Start-Up Air Control and Primary Air Control fully.

4. Make sure that no matches or other combustibles are in the immediate area of the stove. be sure the room is adequately

ventilated and the flue unobstructed.

5. Light the paper in the stove. NeVer light or rekindle stove with kerosene, gasoline, or charcoal lighter fluid; the

results can be fatal.

6. Once the kindling is burning quickly, add several full-length logs 3” (76mm) or 4” (102mm) in diameter. be careful not

to smother the fire. Stack the pieces of wood carefully: near enough to keep each other hot, but far enough away from

each other to allow adequate air flow between them.

7. When ready to reload the stove, add more logs. Large logs burn slowly, holding a fire longer. Small logs burn fast

and hot, giving quick heat.

8. Adjust the Start-Up Air Control and Primary Control; the more you close down the Primary Control, the lower and slower

the fire will burn. The more you open the Primary Control, the more heat will be produced. The Start-Up Air Control

is only used for the first 5 to 15 minutes.

As long as there are hot coals, repeating steps 7 and 8 will maintain a continuous fire throughout the season.
NOTE: The special high temperature paint that your stove is finished with will cure as your stove heats. You will notice an

odor and perhaps see some vapor rise from the stove surface; this is normal. We recommend that you open a window

until the odor dissipates and paint is cured.

NOTE: Stove should be run full open for 15 minutes a day to keep air passages clean.

WARNING! ALWAYS OPERATE THIS APPLIANCE WITH THE DOOR

CLOSED AND LATCHED EXCEPT DURING START-UP AND RE-

FUELING .

WARNING! DO NOT LEAVE THE FIRE UNATTENDED WHEN THE DOOR

IS UNLATCHED. UNSTABLE FIREWOOD COULD FALL OUT OF THE

FIREBOX CREATING A FIRE HAZARD TO YOUR HOME.

CAUTION: Before lighting your first fire in the stove: 1) Make certain that the baffle is correctly positioned. It

should be resting against the rear support; 2) Follow instructions on page 20 for cleaning plated surfaces, and;

3) Remove all labels from glass front.

BUILDING A FIRE

CAUTION: Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to

start or “freshen up” a fire in this heater. Keep all such liquids well away from the heater while it is in use.

For maximum operating efficiency with the lowest emissions, follow these operating procedures:

1. regardless of desired heat output, when loading stove, burn your Quadra-Fire with both air controls wide open for 5 to

15 minutes.

2. regulate burn rate (heat output) by using the Primary Control (center under ashcatcher). The Start-Up Air Control (on the

right) is mainly for initial start-up and reloading.

3. Heat output settings: Following 5 to 15 minutes of burning with controls wide open (

see #1 above):

4. burn dry, well-seasoned wood.

OPERATING INSTRUCTIONS (Cont’d)

IMPORTANT - PLEASE READ BEFORE USING STOVE

WARNING: Do not operate with Start-Up Air

Control in the open position in excess of 15

minutes! "risk of extreme temperatures! Pro-

longed operation of this stove with the Start-

Up Air Control in the open position may cause

the combustible materials around the stove to

exceed safe temperature limits".

BTU / Hr

below 10,000

10,000 - 15,000

15,000 - 30,000

Maximum Heat

Start-Up Air Control

Closed after 5 to 15 minutes

Closed after 5 to 15 minutes

Closed after 5 to 15 minutes

Closed after 5 to 15 minutes

*Primary Control

Pull to Stop

1/8” - 1/2” open

1/2” - 1-1/2” open

Fully open

Advertising