5. 14-pin plug information, 7. motor start control – Hobart Welding Products OLYMPIC S-64 User Manual

Page 18

Advertising
background image

OM-1579 Page 14

4-5.

14-Pin Plug Information

Pin*

Pin Information

A

24 volts ac with respect to socket G.

B

Contact closure to A completes 24 volts ac contactor control circuit.

A

J

G

Circuit common for 24 volts AC circuit.

A

J

B

K

I

C

+10 volts dc output to remote control with respect to socket D.

C

L

N

H

D

M

G

D

Remote control circuit common.

D

M

G

E

F

E

0 to +10 volts dc input command signal from remote control with respect to socket D.

H

Voltage feedback; 0 to +10 volts dc, 1 volt per 10 arc volts.

F

Current feedback; 0 to +10 volts dc, 1 volt per 100 amperes.

*The remaining pins are not used.

4-6.

Wire Type, Size, And Feed Speed Capability Table

Motor Speed

Wire Type

Wire Size

Feed Speed Capability

Standard

All

.023 To 5/64 in (0.6 To 2 mm)

50 To 780 ipm (1.3 To 19.8 mpm)

Standard

All

3/32 To 7/64 in (2.4 To 2.8 mm)

50 To 700 ipm (1.3 To 17.8 mpm)

Standard

All

1/8 in (3.2 mm)

50 To 300 ipm (1.3 To 7.6 mpm)

Optional High

Speed

All

.023 To 5/64 in (0.6 To 2 mm)

92 To 1440 ipm (2.3 To 35.6 mpm)

4-7.

Motor Start Control

802 479 / Ref. 146 862-D

To change wire feed starting speed
proceed as follows:

Turn Off unit and welding power
source.

Remove wrapper.

1

Front Panel

Remove screw from upper left cor-
ner, and open hinged front panel.

2

Motor Board PC1

3

Motor Start Control
Potentiometer R70

Rotate potentiometer clockwise to
increase time it takes the motor to
ramp up to speed. Remove protec-
tive white rubber cap before making
adjustment. Adjust potentiometer
R70 using a small nonconductive
screwdriver.

Close and secure front panel, and
reinstall wrapper.

Tools Needed:

1/4 in

3

Non-Conductive

2

1

Advertising