1. routine maintenance – Hobart Welding Products OLYMPIC S-64 User Manual

Page 22

Advertising
background image

OM-1579 Page 18

5-2.

Overload Protection And Optional Side Panel Controls

802 418-A

1

Circuit Breaker CB1

CB1 protects wire feed motor from
overload. Press to reset.

2

Preflow Control

Control sets time gas flows before
welding wire is energized.

3

Spot Time Control

Factory set for 0 to 5 seconds of
spot time. If 0 to 2.5 seconds is de-
sired, see Section 4-9.

4

Spot Continuous Switch

Switch selects an untimed continu-
ous weld or a timed spot weld.

5

Burnback Control

Control adjusts time welding wire is
energized after wire feed stops.

6

Run-In Control

Control sets run-in wire speed be-
fore arc initiation.

7

Postflow Control

Control sets time gas flows after
completion of burnback.

Close side door.

3

2

5

1

7

4

6

SECTION 6 – MAINTENANCE AND TROUBLESHOOTING

6-1.

Routine Maintenance

Y

Disconnect power before maintaining.

3 Months

Replace
unreadable
labels.

Clean and
tighten
weld
terminals.

Repair or
replace
cracked
weld
cable.

Check
14-pin
cord.

Check gas
hose and
fittings.

Check
gun
cable.

Replace
cracked
parts.

6 Months

Blow out or vacuum
inside. During heavy
service, clean
monthly.

OR

Clean

drive
rolls.

Advertising
This manual is related to the following products: