FUSE REPLACEMENT (HR215HMA)

The electric starter relay circuit and battery charging circuit are
protected by a 1 ampere fuse. If the fuse burns out, the electric starter
will not operate. The engine can be started manually if the fuse burns
out, but running the engine will not charge the battery.

1. Remove the two bolts from the

lower control box cover, using a
10 mm wrench.

2. Remove the lower control box

cover, and check the fuse. If it
is burnt out, install the spare 1
ampere fuse provided with the
mower.

NOTICE

Never use a fuse with a rating
other than 1 ampere. Serious
damage to the electrical system or
a fire can result.

If frequent fuse failure occurs, it
usually indicates a short circuit or
an overload in the electrical
system. Take the mower to an
authorized Honda servicing dealer
for repair.