Hickory industries, inc – HP Hickory Rotisseries 45WDG PLUS User Manual

Page 10

Advertising
background image

Hickory Industries, Inc.

4900 Westside Avenue, North Bergen, New Jersey 07047

Tel: [201] 223-0050 Fax: [201] 223-0950

N/45 Series Manual12/00

Page 10 of 38

Air Intake Adjustment

Lock Nut

Main Orifice

Venturi Tube

Venturi Assembly

1.9

Changing Gas Orifices

1.9.1

Changing the Main Gas Orifice

1.

The venturi tubes and manifold valves are on the same side as the spit handles.

2.

On each venturi, loosen the lock nuts (7/8" wrench) and then move the nut
and the air intake cap all the way to the top of the nipple.

3.

With a 3/4" wrench, loosen the nipple so that it can be removed from the
venturi.

4.

With the nipple/orifice assembly off, separate the main orifice from the
nipple with a pipe wrench or a pair of pliers.

Air Intake Cap

Nipple

Re-assemble all of the components with the new main orifice. Make sure that the proper air intake
adjustment is made for the new type of gas (according to the tables on page 9). The flames should be
blue in color, must be stable, and must not "lift off" the burner.

Advertising
This manual is related to the following products: