1.7.1

Volumetric Method to Verify the High Flame Setting, Mathematical

WARNING! No other gas equipment can be in operation during this procedure.

Calculation of flow rate E in ft

3

/hour

E =

FP
H

i

E = Flow rate in ft

3

/minute

FP = High Flame Power setting in BTU/hr

H

i

=

Heating value in BTU/ft

3

Thus, for natural gas:

E = 60,000

BTU/hr

=

57.75 ft

3

/hr

=

0.96 ft

3

/min.

1040 BTU/ft

3

E = 0.96 ft

3

/min.

Calculation of the natural gas needed in 1 hour by a 45WDG (3 burners) at full power:

57.75 * 3 =

173.25 ft

3

/hr

=

2.89 ft

3

/min.

The time and the flow measurements should be taken at the gas (flow) meter with a
chronometer (stop watch).

To run the test, open the manual gas cock valve, start up the unit according to the start-up
instructions on page 24 and set the manifold valves to the high flame setting ("on" position).

Allow the unit to pre-heat (burn) for 10 to 15 minutes. Verify that the flow rate is calibrated
to the appropriate flow rate indicated in the table.

in ft

3

/hr

Gas Flow

per Burner (40,000 BTU)

BTU/ft³

Heating Value in

Gas

High Flame Setting

Natural

Propane

Butane

1040

57.75

1.7

Natural Gas Flow Table

2500
2500

24.00
24.00