10.

Maintenance Procedures for Continuous Cook Rotisseries

The most effective maintenance procedure that you can perform will be the daily cleaning
procedure.

Monthly:

To ensure that the burner is operating efficiently, remove the ceramics and use a paper clip to clean
any debris from the burner openings.

To ensure proper air/gas mixture, the venturi air inlet gap needs to be cleaned. This can be done
using a paring knife or business card. Refer to the operating manual.

Every 6 Months:

To ensure that the shaft worm nylon gears properly mesh with the spit gears, place a spit into each
spit position with the motor running. If the gears jump or do not align properly, adjust them using
the allen wrench provided – DO NOT OVER TIGHTEN THE SCREWS.

Every 12 Months:

Inspect the spit plates and verify that the brass oil lite bushings are in place for each spit position.
Replace any worn or missing bushings.

Remove the glass and inspect for scratches and or chips. If any are found replace the glass as
soon as possible. Also, inspect the glass trolleys. If they are worn, replace them.

Units with sliding side doors – the upper and lower slides needed to be greased.