OM-2210 Page 12

3-4.

Duty Cycle And Overheating For Non-CE Model

Duty Cycle is percentage of 10 min-
utes that unit can cut at rated load
without overheating.

If unit overheats, thermostat(s)
opens, output stops, Temperature
trouble light goes On, and cooling
fan runs. Wait fifteen minutes for
unit to cool or temperature light to
go off. Reduce amperage or duty
cycle before cutting or gouging.

Y

Exceeding duty cycle can
damage unit and void
warranty.

Overheating

sduty1 5/95 / 801 302-C

3-1/2 Minutes Cutting

6-1/2 Minutes Resting

35% Duty Cycle At 27 Amperes, 91 volts dc

6 Minutes Welding

4 Minutes Resting

Continuous Welding

60% Duty Cycle At 21 Amperes, 88 volts dc

100% Duty Cycle At 17 Amperes, 87 volts dc

35% duty cycle

60% duty cycle

100% duty cycle

For Units Connected to a 20 Ampere, 115 Volt Circuit
or a 10 Ampere, 230 Volt Circuit:

For Units Connected to a 30 Ampere, 115 Volt Circuit
or a 15 Ampere, 230 Volt Circuit:

35% Duty Cycle At 21 Amperes, 88 volts dc

0

15

Minutes

A

OR

Reduce Duty Cycle

3-5.

Duty Cycle And Overheating For CE Model

Duty Cycle is percentage of 10 min-
utes that unit can cut at rated load
without overheating.

If unit overheats, thermostat(s)
opens, output stops, Temperature
trouble light goes On, and cooling
fan runs. Wait fifteen minutes for
unit to cool or temperature light to
go off. Reduce amperage or duty
cycle before cutting or gouging.

Y

Exceeding duty cycle can
damage unit and void
warranty.

Overheating

duty1 4/95 – 801 302-C

230 VAC Input Power: 35% Duty Cycle At 25 Amperes

3-1/2 Minutes Cutting

6-1/2 Minutes Resting

0

15

Minutes

A

OR

Reduce Duty Cycle

115 VAC Input Power: 35% Duty Cycle At 20 Amperes, 20 Ampere Input Circuit

115 VAC Input Power: 35% Duty Cycle At 25 Amperes, 30 Ampere Input Circuit