OM-2210 Page 16

SECTION 4 – OPERATION

4-1.

Controls

Ref. 801 306-C / Ref. 192 492

1

Output Control

Use control to set cutting output.

The yellow zone is for use on 20 A or greater
primary circuits.

Place control in Gas/Air Set position to safely
adjust gas/air pressure. Only gas/air circuit
is activated.

If 20-25 amperes of cutting output is used
with 115 VAC input power, and the overload
protection on the input power circuit fre-
quently opens, either reduce the cutting out-

put and/or the cut time or find more adequate
power (see Section 3-8).
2

Trouble Lights (See Section 5-2)

3

Ready Light

Use light to tell if unit is ready for operation.
Ready light comes on when Power switch is
placed in On position, indicating that all safe-
ty shutdown systems are okay.
If Ready light does not come on, check
Trouble Lights.
4

Power Light

5

Power Switch

Setting Gas/Air Pressure

6

Air Filter/Regulator

7

Pressure Adjustment Knob

Place Output control in Gas/Air position and
turn on gas/air supply. Lift knob and turn to
adjust pressure. Push knob down to lock in
setting.

Place Output control in desired cutting
output.

Setting Gas/Air Pressure

Requires

70-150 PSI

(483-1034 kPa)

Supply

1

4

2

3

5

1

6

7

Set To

60 PSI (414 kPa)