Section 3 − definitions, 1. symbols and definitions, Section 4 − specifications – Hobart Welding Products HANDLER 125 User Manual

Page 15: 1. specifications

Advertising
background image

.

A complete Parts List is available at www.HobartWelders.com

OM-947 Page 11

SECTION 3 − DEFINITIONS

3-1. Symbols And Definitions

A

Amperage

V

Voltage

Hz

Hertz

Negative

Positive

Direct Current

(DC)

Single Phase

Input

Output

Voltage Input

Off

On

Do Not Switch

While Welding

Gas Metal Arc

Welding (GMAW)

Wire Feed

Flux Cored Arc

Welding (FCAW)

Line Connection

Single Phase

Transformer-

Rectifier

S

Suitable For

Welding In An

Environment With

Increased Risk Of

Electric Shock

Percent

U

0

Rated No Load

Voltage (Average)

U

1

Primary Voltage

U

2

Conventional Load

Voltage

I

1

Rated Supply

Current

I

2

Rated Welding

Current

X

Duty Cycle

SECTION 4 − SPECIFICATIONS

4-1. Specifications

Rated Welding

Output

Amperage

Range

Maximum Open-

Circuit Voltage

DC

Amperes Input at

Rated Load Output

115 V, 60 Hz, Single-

Phase

KVA

KW

Weight

W/ Gun

Overall

Dimensions

85 A @ 17.5 Volts

DC, 20% Duty Cycle

60 A @ 20 Volts DC,

20% Duty Cycle*

30 − 125

26

20

15*

2.90

2.20*

2.50

1.77*

50 lb

(22.7 kg)

Length: 16-7/8 in.

(429 mm)

Width: 9-7/8 in.

(251 mm)

Height: 12-1/8 in.

(308 mm)

Wire Type

And Dia

Flux Cored

Solid/

Stainless**

Wire Feed Speed Range

.030 − .035 in.

(0.8 − 0.9 mm)

.024 − .030 in.

(0.6 − 0.8 mm)

0 − 500 IPM (0 − 13 m/min) At No Load

0 − 415 IPM (0 − 11 m/min) Feeding Wire

* CSA Rating
** When shielding gas is required, MIG conversion kit 195 158 may need to be installed.