4-Wire Cord Connections

1. Remove the screws securing the terminal block access cover

and the strain relief mounting bracket located on the back
of the dryer upper corner.

2. Install a U.L. approved strain relief into the power cord entry hole

of the mounting bracket. Finger tighten the nut only at this time.

3. Remove the green neutral ground wire from the green ground

screw located above the terminal block.

green
ground
screw

green neutral
ground wire

green power cord
ground wire

silver terminal

terminal block

tighten nut to
these threads

black

white

nut

strain relief

mounting bracket

power cord

Typical
Conductor
Receptacle

Typical
4 Conductor
Cord

black 240V

white neutral

red 240V

green ground

30 AMP NEMA 14-30 TYPE SRDT OR ST

red

GDZ22-1 manual 10/22/01 11:45 AM Page 21