4. Thread a U.L. approved 30 Amp power cord, NEMA 14-30 type ST

or SRDT through the strain relief.

5. Attach the green power cord ground wire to the cabinet with

green ground screw.

6. Attach the white (neutral) power cord conductor from the power

cord and the green ground wire from the dryer harness to the
silver-colored center terminal on the terminal block. Tighten the
screw securely.

7. Attach the red and black power cord conductors to the outer

brass-colored terminals on the terminal block. Warning: Do not
make a sharp bend or crimp wiring/conductor at connections.

8. Tighten the screws securing the cord restraint firmly

against the power cord.

9. Tighten the strain relief nut securely so that the strain

relief does not turn.

10. Reinstall the terminal block cover.

Caution:

Label all wires prior to disconnection, when servicing
controls. Wiring errors can cause improper operations
and be dangerous. Check unit for proper operation
after servicing.

Warning:

Discard or destroy the carton and plastic bags after the
dryer is unpacked. Children should not be allowed to
use them to play with. Cartons covered with rugs,
bedspreads, or plastic sheets can become an airtight
chamber and cause suffocation leading to death. Make
all packing materials inaccessible to children.

Warning:

The instructions in this manual and all other literature
included with this dryer can not cover every possible
condition and situation that may occur. Good safe
practice and caution must be applied when installing,
operating and maintaining any appliances. After
installing, if you are in doubt, call a certified
electrician to install and wire the dryer.