Step 5. Positioning, Leveling, and

Securing the Fireplace

The diagram below shows how to properly position, level,

and secure the fireplace.

Figure 7. Proper Positioning, Leveling

and Securing of a Fireplace

• Place the fireplace into position (see Figure 7).

• Level the fireplace from side to side and from front to

back.

• Shim the fireplace with non-combustible material, such

as sheet metal, as necessary.

• Secure the fireplace to the framing using nails or screws

through the nailing tabs.

ROOF PITCH

H (MIN.) FT.

FLAT TO 6/12

1.0

6/12 TO 7/12

1.25

OVER 7/12 TO 8/12

1.5

OVER 8/12 TO 9/12

2.0

OVER 9/12 TO 10/12

2.5

OVER 10/12 TO 11/12

3.25

OVER 11/12 TO 12/12

4.0

OVER 12/12 TO 14/12

5.0

OVER 14/12 TO 16/12

6.0

OVER 16/12 TO 18/12

7.0

OVER 18/12 TO 20/12

7.5

OVER 20/12 TO 21/12

8.0

Figure 6. Vent Termination

!

C. Bedroom Installation in Canada

This model MUST NOT be vented into a vent system

installed exterior to a building. The part of the vent system

above the roof line can be exterior to the building.

D. Vent Termination

WARNING: MAJOR U.S. BUILDING CODES

SPECIFY MINIMUM CHIMNEY AND/OR VENT

HEIGHT ABOVE THE ROOF TOP. THESE

MINIMUM HEIGHTS ARE NECESSARY IN THE

INTEREST OF SAFETY. FIGURE 6 AND TABLE

SHOW MINIMUM HEIGHTS, PROVIDED THE

TERMINATIONS CAP IS AT LEAST 8-FEET

FROM A VERTICAL WALL.

H (MIN.)-MINIMUM HEIGHT FROM ROOF
TO LOWEST DISCHARGE OPENING

VENT CAP

LOWEST DISCHARGE OPENING

12

X

ROOF PITCH IS X/12

NAILING TABS