OM-222 Page 17

3-8.

Weld Output Terminals And Selecting Cable Sizes

Total Cable (Copper) Length In Weld Circuit Not Exceeding

100 ft (30 m) Or Less

150 ft

(45 m)

200 ft

(60 m)

250 ft

(70 m)

300 ft

(90 m)

350 ft

(105 m)

400 ft

(120 m)

Y

Turn Off power before

connecting to weld output

terminals

Welding

Amperes

10 – 60%

Duty

Cycle

60 – 100%

Duty Cycle

10 – 100% Duty Cycle

100

4

4

4

3

2

1

1/0

1/0

150

3

3

2

1

1/0

2/0

3/0

3/0

200

3

2

1

1/0

2/0

3/0

4/0

4/0

250

2

1

1/0

2/0

3/0

4/0

2-2/0

2-2/0

300

1

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-3/0

350

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-3/0

2-4/0

400

1/0

2/0

3/0

4/0

2-2/0

2-3/0

2-4/0

2-4/0

Electrode

Work

500

2/0

3/0

4/0

2-2/0

2-3/0

2-4/0

3-3/0

3-3/0

600

3/0

4/0

2-2/0

2-3/0

2-4/0

3-3/0

3-4/0

3-4/0

700

4/0

2-2/0

2-3/0

2-4/0

3-3/0

3-4/0

3-4/0

4-4/0

800

4/0

2-2/0

2-3/0

2-4/0

3-4/0

3-4/0

4-4/0

4-4/0

Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.

S-0007-D

3-9.

Remote 14 Receptacle Information

Socket

Information

A

24 volts ac. Protected by circuit breaker CB2.

24 VOLTS AC

B

Contact closure to A completes 24 volts ac contactor control circuit.

C

Command reference; 0 to +10 volts dc.

REMOTE OUTPUT CONTROL

D

Remote control circuit common.

E

0 to +10 volts dc input command signal from remote control.

F

Current feedback; 1 volt per 100 amperes.

H

Voltage feedback; 1 volt per 10 arc volts.

I

115 volts, 15 amperes, 60 Hz ac. Protected by circuit breaker CB1.

115 VOLTS AC

J

Contact closure to I completes 115 volts ac contactor control circuit.

GND

K

G

Chassis common.

Circuit common for 24 and 115 volts ac circuits.

*

REMOTE POWER ON/OFF

*

To remote On/Off switch.

*

Voltage sensing signal from Negative (-) weld output terminal.

REMOTE VOLTAGE SENSING

*

Voltage sensing signal from Positive (+) weld output terminal.

* Not Used