13. connecting input power, Important – Hobart Welding Products 652 User Manual

Page 25

Advertising
background image

OM-222 Page 21

3-13. Connecting Input Power

ST-800 103-B / Ref. ST-801 116

3/8 in

3/8 in

Tools Needed:

IMPORTANT

GND/

3

PE Connect Green Or Green/Yellow

GND/PE Conductor First.

Input Contactor

L1 (U)

L2 (V)

L3 (W)

= GND/PE Earth Ground

1

10

3

When making connections in
the line disconnect device,
connect the Green Or
Green/Yellow conductor first.

Install conductors into
a deenergized line dis-
connect device.

Make connections
to machine first and
supply last.

4

9

6

5

2

3

7

3

8

Y

Disconnect and lockout/tagout in-
put power before connecting input
conductors from unit.

Y

Have only qualified persons make
this installation.

See rating label on unit and check input
voltage available at site.

1

Line Disconnect Device

2

Input Conductors

3

Grounding Conductor

Select size and length using Section 3-11.
Conductors must comply with national,
state, and local electrical codes. If applica-
ble, use lugs of proper amperage capacity
and correct hole size.

4

Strain Relief

Route conductors through strain relief.

5

Machine Grounding Terminal

6

Line Terminals

Y

Make input power connections to
the welding power source before
making connections into a deener-
gized line disconnect device.

Connect green or green/yellow grounding
conductor to machine grounding terminal
first. Then connect input conductors to line
terminals.

Close access door.

7

Disconnect Device (Supply)
Grounding Terminal

8

Disconnect Device Line Terminals

Y

In the deenergized line disconnect
device, connect green or green/
yellow grounding conductor to
supply grounding terminal first,
never to a line terminal. Be sure
grounding conductor goes to an
earth ground.

Connect input conductors to line termi-
nals.

9

Overcurrent Protection

Select type and size using Section 3-11
(fused disconnect switch shown).

Close door on line disconnect device.

10 Reed Switch (Ground Current

Sensor) (Optional)

If unit is equipped with optional ground cur-
rent sensor, route grounding conductor
through reed switch two times and con-
nect to ground terminal.

Close access door.

Advertising
This manual is related to the following products:

452, 302