Warning, 4300 wood stove series (acc), B. clearances to combustibles (ul and ulc) – Hearth and Home Technologies Quadra-Fire 43ST-ACC User Manual

Page 11

Advertising
background image

September 1, 2008

7037-135E

Page 11

4300 Wood Stove Series (ACC)

R

B. Clearances to Combustibles (UL and ULC)

BACKWALL / SIDEWALL

CORNER INSTALLATION

90° OFF TOP

UP & OUT CEILING

CLEARANCE

STOVE TO CEILING

CLEARANCE

ALCOVE TOP VIEW

A

B

ALCOVE SIDE VIEW

NOTE: Clearances may only be reduced by means

approved by the regulatory authority having jurisdiction

Fire Risk.
• Comply with all minimum clearances to

combustibles as specified.

• Failure to comply may cause house fire.

WARNING

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS In Inches & (Millimeters)

NOTE: All "A" , "C" and "F" Dimensions are to the inside diameter of the flue collar.

A

B

C

D

E

F

G

H

INSTALLATION: Full Vertical OR Horizontal with Minimum 2 FT Vertical Off Stove Top

SINGLE WALL PIPE

Flat Top Model

15.5 (394) 11.75 (298) 24.5 (622) 14.5 (368)

10 (254) 17.5 (445) 53.5 (1359) 12 (305)

Step-Top Model

15.5 (394) 11.75 (298) 24.5 (622) 14.5 (368)

2 (51)

12 (305) 49.5 (1283) 12 (305)

DOUBLE WALL PIPE

Flat Top Model

9 (229)

5.25 (133) 24.5 (622) 14.5 (368)

10 (254) 17.5 (445) 53.5 (1359) 12 (305)

Step-Top Model

7.5 (191) 3.75 (95)

22 (559) 11.75 (298)

2 (51)

12 (305) 49.5 (1283) 5 (127)

INSTALLATION: 90° Elbow Off Top of Stove Through Backwall

DOUBLE WALL PIPE

Flat Top Model

8.5 (216)

6 (152)

24.5 (622) 15 (381)

10 (254) 17.5 (445) 53.5(1359)

N/A

Step-Top Model

7.5 (191)

4 (102)

19 (229)

9 (229)

2 (51)

12 (305) 49.5 (1283)

N/A

INSTALLATION: ALCOVE Six inch (6") (152mm) diameter listed Double Wall air insulated connector pipe with UL103 HT* listed

factory-built Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor). Maximum depth of Alcove

shall be no more than 48 inches (1220mm) with a minimum height of 49.5 inches (1283mm) to top of unit, and the referenced clearances.

*In Canada must comply with CAN/ULC-S269 M87 for the 650

o

C Factory-built chimney.

DOUBLE WALL PIPE

Flat Top Model

13 (330)

10 (254) 24.5 (622) 14.5 (368)

N/A

N/A

53.5 (1359) 12 (305)

Step-Top Model

7.5 (191) 3.75 (95)

22 (584) 11.75 (298)

N/A

N/A

49.5 (1257) 5 (127)

NOTE: Service Space
In order to replace the tube channel assembly a clearance

of 19 inches (48mm) is required on the right side of stove

in order to remove the tubes with the stove in place.
If space is not available, the stove will have to be discon-

nected from the chimney to proceed with the tube replace-

ment.

See Figure 36 on page 36.

Advertising