Troubleshooting, Warning – Hitachi 308640 User Manual

Page 14

Advertising
background image

14 308640

Troubleshooting

WARNING

INJECTION HAZARD
To reduce the risk of a fluid injection
injury, follow the Pressure Relief Proce-
dure
on page 7 before checking or

servicing any of the system equipment and when-
ever you are instructed to relieve pressure.

NOTE:

D

Check all possible remedies in the troubleshooting
charts before disassembling the gun.

D

Some improper patterns are caused by the
improper balance between air and fluid.

General Troubleshooting

Problem

Cause

Solution

Fluid leakage from back of fluid
needle

Worn packings or needle shaft

Replace external needle packings or
entire fluid needle cartridge. See
page 16.

Air leakage from front of gun

Air valve not seating properly

Clean/service air valve. See page 16.

Fluid leakage from front of gun

Fluid needle worn or damaged

Replace fluid needle cartridge. See
page 16.

Worn diffuser-seat housing

Replace the diffuser-seat and gasket.
The gasket must be replaced when-
ever the diffuser-seat is removed.
See page 16.

Fluid in air passages

Fluid tip seal leaking

Tighten or replace fluid tip.

g

Leaking around diffuser-seat housing

Replace the diffuser-seat gasket. The
gasket must be replaced whenever
the diffuser-seat is removed. See
page 16.

Fluid inlet fitting leaking

Replace the fluid fitting gasket. The
gasket must be replaced whenever
the fluid fitting is removed. See
page 17.

Slow fluid shut-off

Fluid buildup on fluid needle cartridge
components.

Diffuser-seat is overtightened.

Remove and clean or replace the
fluid needle cartridge. See page 16.

Remove diffuser-seat and replace
diffuser-seat gasket. Torque diffuser-
seat to 90–100 in-lb (10.2–11.2
N

S

m).