Heat & Glo Fireplace HEAT & GLO ESCAPE-I35-C User Manual

Page 19

Advertising
background image

19

Heat & Glo • Escape-I35-C, Escape-I30-C • 2201-901 Rev. K • 1/13

Figure 5.2 Fireplace Opening

In addition to these dimensions, also reference
Clearances and Mantel Projections (Section 5.B).

E

FRONT VIEW

D

C

F

A

TOP VIEW

B

G**

H

MINIMUM FIREPLACE SIZE

Location

ESCAPE-I35-C

ESCAPE-I35LP-C

ESCAPE-I30-C

ESCAPE-I30LP-C

Inches

Millimeters

Inches

Millimeters

A

Rear Width

25-1/2

648

21-1/2

546

B

Front Width

35

889

30-1/4

768

C

Glass Opening Width

31-1/2

800

26-3/4

679

D

Glass Opening Height

20

508

18

457

E

Height-Front

24-7/8

632

22-7/8

581

F

Height-Rear

22-1/4

565

20-5/8

524

G**

Unit Depth

18-1/4

464

16-7/8

429

H

Venting Depth

13-3/8

340

12-1/8

308

* Note: If exhaust collar on insert and fi replace damper do not line up, add 4 inches (102 mm) to minimum

fi replace height for bends in vent pipe.

**Unit depth is measured to the back of the surround to give the depth needed for installation.

Advertising