Maintenance – Husqvarna 16 H User Manual

Page 27

Advertising
background image

English –

25

MAINTENANCE

BioClip 103

Replacing the cutting unit belts

Replacing the belts on a BioClip unit

A BioClip unit is driven by two toothed belts that
synchronise the rotation of the blades. The belts sit
underneath a cover on the cutting unit.

1. Remove the cutting unit, see page 24.

2. Remove the front pin/bolt from the lift strut and

swing the strut backwards.

4. Unscrew the nut from the cam and twist the cam

off.

Undo the four nuts (see diagram) that hold the
outer blade bearing, just enough to allow the
bearing to be moved.

Slide the blade bearing inwards towards the middle
bearing and prise off the upper belt.

Repeat the procedure with the lower belt.

WARNING!

Wear gloves to protect your hands
when working with the blades.

!

BioClip 103

3. Undo the two screws that hold the safety cover

and lift the cover off.

BioClip 103

Advertising