33
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
[c] LOW ICE PRODUCTION 
 
 
 
 
 
 
 
 
 
 
 
 
[d] ABNORMAL ICE 
 
 
 
 
 
a) See chart [b] [1] and check float switch, fill and harvest water valves, control
board, water pump, spray tubes, evaporator, and expansion valve.
b) See chart [a] [1] and check dirty air filter or condenser, ambient or water
temperature, refrigerant charge, water pressure, and condenser water 
regulating valve (water-cooled model only).
a) See chart [b] [2] and check evaporator, water supply line, harvest water valve,
ambient and/or water temperature, line valve (if applicable), thermistor, control 
board, and hot gas valve.
a) Ice Cube Guide,
Water Tank, 
Deflector
1. See "II. 3. [d] Control
Board Check Procedure."