4-10. Wiring Optional 240 Volt Plug (119 172) For Connection To Bobcat, Trailblazer Or

Champion 10,000

Ref. 120 813-D / Ref. 803 222

1

Input And Grounding
Conductors

2

Plug Wired for 240 V, 2-Wire
Load

3

Neutral (Brass) Terminal And
Prong (Not Used)

4

Load 1 (Brass)Terminal And
Prong

5

Load 2 (Brass) Terminal And
Prong

6

Ground (Brass) Terminal And
Prong

7

Black And White Input
Conductors

8

Green Or Green/Yellow
Ground Conductor

Y

Always connect green or
green/yellow wire to ground
terminal, never to a load
terminal. Connect black (L1)
and white (L2) wires to load
terminals.