f) LED Lights and Audible Alarm Safeties

The red LED indicates proper control voltage and will remain on unless a control voltage
problem occurs. At startup a 5 second delay occurs while the board conducts an internal
timer check. A short beep occurs when the power switch is turned OFF.
The green LEDs 1 through 4 energize and sequence from initial startup as listed in the
table below. Note that the order of the LEDs from the outer edge of the board is 1, 4, 3,
2. For more information, see "II.B. Sequence of Operation."

Sequence Step

LED

Energized

Components

Time LEDs are On

Min.

Max.

Avg.

1 Minute Fill Cycle 4

WV

60 seconds

Harvest Cycle

1, 4, and 2

WV, HGV,
Comp, FMR

2 minutes 20 minutes 3 to 5 minutes

Freeze Cycle

1

Comp, PM,
FMR/FMS,
LLV

5 minutes freeze timer

setting

30 to 35 minutes

Reverse Pump Out 1, 3, and 2

Comp, HGV,
PM, FMR

10 seconds 20 seconds factory setting

The built in safeties shut down the unit and have alarms as follows:

No. of Beeps

(every 3 sec.)

Type of Alarm

Notes

1

High Evaporator Temp.
(temperature > 127°F)
(53°C)

Check for harvest problem (stuck HGV or
relay), hot water entering unit, stuck HM,
or shorted thermistor.

2

Harvest Backup Timer
(harvest > 20 min. for two
cycles in a row)

Orange LED marked H TIMER lights up.
Check for open thermistor, HGV not
opening, TXV leaking by, low charge, or
inefficient compressor.

3

Freeze Timer
(freeze > specified setting
for two cycles in a row)
Timer is factory set using
dip switches 9 & 10

Yellow LED marked F TIMER lights up.
Check for F/S stuck closed (up), WV
leaking by, HGV leaking by, TXV not
feeding properly, low charge, HM not
bypassing, or inefficient compressor.

To manually reset the above safeties, press the alarm reset button with the power
supply on.

6

Low Voltage
(92Vac ±5% or less)

Red LED will turn off if voltage protection
operates.
The control voltage safeties automatically
reset when voltage is corrected.

7

High Voltage
(147Vac ±5% or more)

Legend:

Comp–compressor; FMR–remote fan motor; FMS–self-contained fan motor;

F/S–float switch; HGV–hot gas valve; HM–headmaster (C.P.R.); LLV–Liquid

Line Valve;

PM–pump motor; TXV–thermostatic expansion valve; WV–inlet

water valve