Hoshizaki MODULAR CRESCENT CUBER KM-650MWH User Manual

Page 33

Advertising
background image

33

Problem

Possible Cause

Remedy

[1] The icemaker will not

start. (continued)

e)High Pressure Control

(continued)

3. Ambient or condenser

water temperature too
warm.

3. Reduce temperature.

4. Refrigerant

overcharged.

4. Recharge.

5. Fan not operating.

(except water-cooled
model)

5. See chart 1.[6]

6. Refrigerant line or

components plugged.

6. Clean and replace drier.

7. Condenser water

pressure too low or off.
(water-cooled model
only)

7. Check and get

recommended pressure.

f) Transformer

1. Coil winding opened

or shorted.

1. Replace.

g)Wiring to Control Board 1. Loose connections or

open.

1. Check for continuity and

replace.

h)Thermistor

1. Leads shorted or

opened and high
temperature or harvest
backup timer safety
operates. (1 beep or 2
beep alarm)

1. See "II.C.3. Controls and

Adjustments, b) Harvest
Control."

i) Hot Gas Valve

1. Continues to open

in freeze cycle and
freeze timer safety
operates. (3 beep
alarm)

1. Check for hot gas valve

stuck open and replace.

j) Water Supply Line

1. Water supply off and

water supply cycle
does not finish.

1. Check and get

recommended pressure.

2. Condenser water

pressure too low
or off and pressure
control opens and
closes frequently to
finally operate high
temperature safety.
(1 beep alarm)

2. Check and get

recommended pressure.

k) Inlet Water Valve

1. Mesh filter or orifice

gets clogged and
water supply cycle
does not finish.

1. Clean.

2. Coil winding opened. 2. Replace.
3. Wiring to water valve. 3. Check for loose

connection or open, and
replace.

l) Control Board

1. Defective.

1. See "II.C.4. Control Board

Check Procedure."

Advertising
This manual is related to the following products: