Km-650mwh (water-cooled) – Hoshizaki MODULAR CRESCENT CUBER KM-650MWH User Manual

Page 6

Advertising
background image

6

2. KM-650MWH (water-cooled)

Note: We reserve the right to make changes in specifications and design without prior

notice.

SPECIFICATION NO. 06A020

ISSUED: 10/10/2006

ITEM: HOSHIZAKI MODULAR CRESCENT CUBER

MODEL: KM-650MWH
AC SUPPLY VOLTAGE

208-230/60/1 (3 wire with neutral for 115V)

AMPERAGE

5.3 A ( 5 Min. Freeze AT 104°F / WT 80°F)

MINIMUM CIRCUIT AMPACITY

15 A

MAXIMUM FUSE SIZE

15 A

APPROXIMATE ICE PRODUCTION

Ambient

WATER TEMP. (°F)

PER 24 HR.

Temp.(°F)

50

70

90

lbs./day ( kg/day )

70

*680 (308)

675 (306)

626 (284)

Reference without *marks

80

676 (307)

668 (303)

595 (270)

90

675 (306)

*662 (300)

598 (271)

100

651 (295)

647 (294)

540 (245)

SHAPE OF ICE

Crescent Cube

ICE PRODUCTION PER CYCLE

14.8 lbs. (6.7 kg) 720 pcs.

APPROXIMATE STORAGE CAPACITY

N/A

ELECTRIC & WATER CONSUMPTION

90/70°F

70/50°F

ELECTRIC W (kWH/100 lbs.)

1050(3.8)

1020(3.6)

WATER gal./24HR (gal./100 lbs.)

149(22.5)

254(37.4)

WATER COOLED CONDENSER

741(112)

408(60)

gal./24HR (gal./100 lbs.)

EXTERIOR DIMENSIONS (WxDxH)

22" x 27-3/8" x 37-7/16" (560 x 695 x 950 mm)

EXTERIOR FINISH

Stainless Steel, Galvanized Steel (Rear)

WEIGHT

Net 169 lbs. (77 kg), Shipping 200 lbs. (91 kg)

CONNECTIONS - ELECTRIC

Permanent - Connection

- WATER SUPPLY

Inlet

1/2" FPT

Condenser Inlet 1/2" FPT

- DRAIN

Outlet

3/4" FPT

Condenser Outlet 3/8" FPT

3/8" OD Tube

CUBE CONTROL SYSTEM

Float Switch

HARVESTING CONTROL SYSTEM

Hot Gas and Water, Thermistor and Timer

ICE MAKING WATER CONTROL

Timer Controlled. Overflow Pipe

COOLING WATER CONTROL

Pressure Regulator

BIN CONTROL SYSTEM

Thermostat

COMPRESSOR

Hermetic, Model RS55C2E-CAV

CONDENSER

Water-cooled, Tube in tube type

EVAPORATOR

Vertical type, Stainless Steel and Copper

REFRIGERANT CONTROL

Thermostatic Expansion Valve

REFRIGERANT CHARGE

R-404A, 1 lb. 5.7 oz. (615g)

DESIGN PRESSURE

High 427PSIG, Low 230PSIG

P.C. BOARD CIRCUIT PROTECTION

High Voltage Cut-out ( Internal )

COMPRESSOR PROTECTION

Auto-reset Overload Protector ( Internal )

REFRIGERANT CIRCUIT PROTECTION

Auto-reset High Pressure Control Switch

LOW WATER PROTECTION

Float Switch

ACCESSORIES -SUPPLIED

N/A

-REQUIRED

Ice Storage Bin

OPERATING CONDITIONS

VOLTAGE RANGE

187 - 253 V

AMBIENT TEMP.

45 -100° F

WATER SUPPLY TEMP.

45 - 90° F

WATER SUPPLY PRESSURE

10 - 113 PSIG

DRAWING NO. (DIMENSION)

3A1898

We reserve the right to make changes in specifications and design without prior notice.

ENG.F-011.1.0205

Advertising
This manual is related to the following products: