Menu functions – Husqvarna 230 ACX User Manual

Page 51

Advertising
background image

52 - English

6. MENU FUNCTIONS

Up to five remote areas can be activated: Area 1,
Area 2, Area 3, Area 4 and Area 5
(only three
areas on 220 AC). Three values need to be
stated to activate an area:

• Direction

Specify to the right, left, guide 1 or guide 2
depending on which direction the area lies from
the charging station. The direction is set
looking from the charging station in the
approach direction of the mower.

When a guide wire is installed the direction can
be specified as the guide wire. The mower will
now follow the selected guide wire instead of
the boundary wire, (only guide 1 is available on
220 AC).

• Distance

Specify the number of metres along the
boundary wire or guide wire from the charging
station to the place in the remote area where the
mower shall start mowing.

Tip!

Use the Test OUT (3-2-5) function (see

page 55) to find out how far it is to the remote
area. The distance, stated in metres, will appear
on the mower display.

• Proportion

Specify a value for how often of the occasions
Automower leaves the charging station it should
follow the loop out to the remote area.

For example the value 20 % means that in 20 %
of the occasions Automower leaves the charging
station, it does it in the direction to the remote
area. In the remaining 80 % of the occasions the
mower leaves the charging station according to
the setting made for its function Exit angles
(3-1)
.

If a value of 20 % is specified for Area 1 and
10 % for Area 2, the remaining 70 % is allocated
to the selection under Exit angles (3-1).

3-2-1

Area 1

Area 2

Area 3

Area 4

Area 5

Follow loop out

Follow loop in

Corridor width

Test IN

Test OUT

Direction

Distance

Proportion

Area 1

Area 2

Area 3

Area 4

Area 5

Right

Left

Guide 1

Guide 2

Direction

Distance

Proportion

Advertising